1. INTRODUCTION
The PowerMaster-10 is a user and installer-friendly, 29-zone fully-supervised wireless control system.
The system is designed to function in an appealing way to the user and also offers features that make installers’
life easier than ever before:
EASY TO MAINTAIN
Alarm memory and trouble data are displayed upon request.
Diagnostic test provides visual and audible indication of the signal level of each detector.
Remote control from distant telephones.
Event log stores and displays information.
Upload / download from distant computer via telephone line or cellular modem.
QUICK PROGRAMMING
Simple programming logic, fully menu driven.
Multiple-choice selection of options for each parameter.
Unequivocal visual prompts.
Installer access to the user menu.
2. SPECIFICATIONS
2.1 Functional
Zones Number
28 wireless zones, 1 hardwired input.
Hardwired Zone Requirements
2.2 kΩ E.O.L. resistance (max. resistance of wires 220 Ω).
Zone Types
Interior follower, interior, perimeter, perimeter follower, delay 1, delay 2,
home delay, interior-follow, interior, perimeter, perimeter-follow, 24h silent,
24h audible, emergency and non-alarm.
User Codes
8 codes, 4 digits each (9999 different combinations). Code 0000 is not
allowed.
Control Facilities
- Integral keypad
- SMS commands via optional GSM/GPRS module.
- Remote control by telephone.
Note: For SIA CP-01 compliance, when using KF-234 PG2 an external
siren must also be used.
Display
Single line, backlit 16-character LCD.
Arming Modes
AWAY, HOME, AWAY-INSTANT, HOME-INSTANT, LATCHKEY,
FORCED, BYPASS.
Alarm inhibited during a single
arming period (swinger stop)
after
1, 2, 3, alarm/tamper/fault, or not inhibited (programmable / selectable).
Note: To comply with EN requirements, the swinger stop should be set to
3.
Alarm Types
Silent alarm, personal emergency alarm, burglary alarm and fire alarm.
Siren Signals
Continuous
(intrusion / 24 hours / panic); triple pulse - pause - triple
pulse... (fire).
Siren (bell) Timeout
Programmable (4 min. by default)
Internal Sounder Output
At least 85 dBA at 10 ft (3 m)
Supervision
Programmable time frame for inactivity alert
Special Functions
- Chime zones
- Diagnostic test and event log.
- Local and Remote Programming over Telephone, GSM /GPRS connections.
- Calling for help by using an emergency transmitter.
- Tracking inactivity of elderly, physically handicapped and infirm people.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMASTER-10 - INSTALLER GUIDE and is the answer not in the manual?

Visonic POWERMASTER-10 - INSTALLER GUIDE Specifications

General IconGeneral
CategorySecurity System
ModelPOWERMASTER-10
Wireless ProtocolPowerG
Backup BatteryYes
User CodesUp to 48 user codes
TypeWireless Alarm System
Partitions3
CommunicationGSM
Wireless Frequency868 MHz
KeypadsUp to 8 keypads
Event Log1000 events
Power SupplyExternal power supply
Backup Battery Voltage7.2V
Operating Temperature-10°C to +50°C
Humidity85% non-condensing
ZonesUp to 30 wireless zones