D-302756 43
You can now press the or button to program any other
menu in "
DEFINE PANEL
" or press the button to take you to "
<OK>
TO EXIT
".
4.8.2 Configuring Swinger Stop
Here you determine the number of times each zone is allowed to initiate an alarm within a single
arming/disarming period (including tamper & power failure events of detectors, PowerMaster-10, wireless siren,
etc.). If the alarms number from a specific zone exceeds the programmed number, the control panel
automatically bypasses the zone to prevent recurrent siren noise and nuisance reporting to the Monitoring
Station. The zone will be reactivated upon disarming, or 48 hours after having been bypassed (if the system
remains armed).
Available options are: shut after 1 (default), shut after 2 (default in USA), shut after 3 and no shutdown.
To Configure Swinger Stop
1.
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
2.
3.
or
4.
5.
or
Select between "shut after 1", "shut after 2", "shut after 3"
and "no shutdown".
6.
You can now press the or button to program any other
menu in "
DEFINE PANEL
" or press the button to take you to "
<OK>
TO EXIT
".
4.8.3 Enable Monitoring of Activity at Home
Here you determine the time limit for reception of signals from sensors used to monitor the activity of sick,
elderly or disabled people. If no sensor detects and reports movement at least once within the defined time limit,
a “not-active” alert is initiated.
Options: 3, 6, 12, 24, 48, 72 hours and no act disable (default).
To Configure Monitoring of Activity at Home
1.
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
2.
3.
or
01:ENTRY DELAY 1
DEFINE PANEL
13:SWINGER STOP
shut after 1
13:SWINGER STOP
01:ENTRY DELAY 1
DEFINE PANEL
14:CROSS ZONING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMASTER-10 - INSTALLER GUIDE and is the answer not in the manual?

Visonic POWERMASTER-10 - INSTALLER GUIDE Specifications

General IconGeneral
CategorySecurity System
ModelPOWERMASTER-10
Wireless ProtocolPowerG
Backup BatteryYes
User CodesUp to 48 user codes
TypeWireless Alarm System
Partitions3
CommunicationGSM
Wireless Frequency868 MHz
KeypadsUp to 8 keypads
Event Log1000 events
Power SupplyExternal power supply
Backup Battery Voltage7.2V
Operating Temperature-10°C to +50°C
Humidity85% non-condensing
ZonesUp to 30 wireless zones