58  D-302756 
4.12.2 Define PGM 
For the PGM output, you can select disable, turn on, turn off or pulse active (turn on for predefined period, 
selected by PULSE TIME), as follows:  
  ARM AWAY (upon AWAY arming). 
  ARM HOME (upon HOME arming). 
  DISARM (upon disarming). 
  MEMORY (activated upon registration of an alarm in the memory, turned off upon memory clearing). 
  DELAY (during exit / entry delays). 
  KEYFOB (upon AUX button pressing in the keyfob transmitter). 
  ZONES (by disturbance in each
 of 3 selected zones, irrespective of arming / disarming). If you select toggle, 
the PGM output will be turned on upon event occurrence in these zones and will be turned off upon next 
event occurrence, alternately.  
  LINE FAIL: PGM output is ON if telephone line is disconnected. 
For PGM devices, you can select the following actions: 
 FLASH ON ALARM - you can select no flash or all light flash, to control PGM lighting devices in alarm 
conditions. 
  LOCKOUT TIME - you can enter daytime limits between which PGM lighting devices controlled by sensors will 
be off, even when the associated sensors are triggered. 
A. To Configure Output Parameters 
1. 
 
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu". 
 
 
2. 
 
 
 
 
There are two sub-menus "DEFINE PGM" and "PGM GENERAL DEF". 
The PowerMaster-10 display will first read "DEFINE PGM". 
3. 
 
 
 
 
 
4. 
 
 
 
 
 
5. 
 or   
Select between "pulse time 2s", "pulse time 30s", "pulse time 
2m" and "pulse time 4m" 
6. 
 
 
 
 
 
7. 
 
 
 
 
 
8. 
 or   
Select between "disable", "turn ON", "turn OFF" and "pulse 
active". 
9. 
 
 
 
 
 
10. 
 
 
 
 
 
11. 
 
 
 
 
 
12. 
 or   
Select between "disable", "turn ON", "turn OFF" and "pulse 
active". 
disable   
 
PGM: BY ARM HOME 
PGM: BY ARM AWAY 
disable   
 
PGM: BY ARM AWAY 
pulse time 2s 
 
PGM: PULSE TIME 
DEFINE PGM 
DEFINE OUTPUTS