8 READING THE EVENT LOG
Events are stored in the event log. You can access this log and review the events, one by one. If the event log
fills up completely, the oldest event is deleted upon registration of each new event.
The
date and time of occurrence are memorized for each event.
When reading the event log, events are shown in chronological order - from the newest to the oldest. Access to the
event log is provided by pressing the
button and not through the installer’s menu. The reading and erasing
process of the event log is shown below.
8.1 Reading the Event Log
1.
While the system is in the normal operating mode, press the
key.
2.
Enter the current installer code.
3.
The latest event is shown.
The event is displayed in two parts, for example, "Z13 alarm" then
"09/02/10 3:37 P".
4.
Press the
button repeatedly to scroll through the list of events.
Pressing the or buttons at any stage in the procedure
will take you to “
<OK> TO EXIT
”.
8.2 Erasing and Exiting the Event Log
5.
From anywhere within the event log, press the
button.
Note: This is applicable only if the installer code entered.
6.
At this stage in the procedure, pressing the
or buttons
will take you to
<OK> TO EXIT
” without erasing the event log. Pressing
the
button will return you to “
CLEAR EVENT LOG
”.
7.
8.
The system erases the event log and reverts to the normal operating
mode.
Pressing the or buttons at any stage in the procedure
will take you to “
<OK> TO EXIT
”.
READY 00:00
<OK> TO EXIT
<OFF> to delete
CLEAR EVENT LOG
09/02/10 3:37 P
Z13 alarm
09/02/10 3:37 P
Z13 alarm
LIST OF EVENTS
READY 00:00
ENTER CODE:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMASTER-10 - INSTALLER GUIDE and is the answer not in the manual?

Visonic POWERMASTER-10 - INSTALLER GUIDE Specifications

General IconGeneral
CategorySecurity System
ModelPOWERMASTER-10
Wireless ProtocolPowerG
Backup BatteryYes
User CodesUp to 48 user codes
TypeWireless Alarm System
Partitions3
CommunicationGSM
Wireless Frequency868 MHz
KeypadsUp to 8 keypads
Event Log1000 events
Power SupplyExternal power supply
Backup Battery Voltage7.2V
Operating Temperature-10°C to +50°C
Humidity85% non-condensing
ZonesUp to 30 wireless zones

Related product manuals