D-302756 69
See the table below for a complete list of possible LAN messages.
If there are no wireless devices enrolled in the PowerMaster-10
system, the PowerMaster-10 display reads "
NO DEVICES
".
** When the button is pressed the test result takes up to 4 min.
before it is displayed, depending on the severity of the failure.
Pressing the or buttons at any stage in the procedure
will take you to
<OK> TO EXIT
” or pressing the
button at the
end of the procedure will take you to the "
LAN RESET OPTION
" menu.
The following LAN messages are reported:
Message Description
Unit is ok PowerLink Broadband Module is functioning correctly.
Test aborted The diagnostic test is aborted, as follows:
AC failure – PowerLink Broadband Module is set to OFF mode.
PowerLink Broadband Module has not completed the power-up procedure. In
this case, the installer should wait a maximum of 30 seconds before re-
testing.
Comm. loss The RS-232 serial interface between the PowerLink Broadband Module and the
PowerMaster-10 failed.
Rcvr Ip missing Receivers IP 1 and 2 settings are missing in the PowerMaster-10.
Cable unplugged The Ethernet cable is not connected to the PowerLink Broadband Module.
Check lan config This message appears in any of the following cases:
Incorrect PowerLink Broadband Module IP has been entered.
Incorrect subnet mask has been entered.
Incorrect default gateway has been entered.
DHCP server failure.
Rcvr#1 UnReach.
Rcvr#2 UnReach.
Receiver 1 or 2 is inaccessible, as follows:
Wrong receiver IP has been entered.
Receiver failure.
WAN Network failure.
Rcvr#1 UnReg.
Rcvr#2 UnReg.
The PowerMaster-10 unit is not registered to IP receiver 1 or 2.
Broadband Module timeout
err.
PowerLink Broadband Module does not respond to test result within 70 sec.
Invalid result PowerLink Broadband Module responds with a result code that is not recognized
by the PowerMaster-10.
5.1.7 LAN Reset Option
1.
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
2.
*
3.
or
4.
REBOOT
LAN RESET OPTION
WL DEVICES
DIAGNOSTICS