D-302756 27
4.
5.
or
Select between "disable on fail" and "enable on fail".
6.
You can now press the or button to program any other
menu in "
DEFINE PANEL
" or press the button to take you to "
<OK>
TO EXIT
".
4.7 Event Reporting Configuration
4.7.1 General
The PowerMaster-10 system uses an IP platform that supports GSM and GPRS cellular communication and
broadband to forward all events received at the control panel to the monitoring station.
4.7.2 Setup Report Communicators
4.7.2.1 Configuring PSTN / GSM Communicators
1.
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
2.
3.
4.
TEL. AREA CODE
Enter the system tel. area code (up to 4 digits).
5.
6.
7.
LINE PREFIX
Enter the number that is used as a prefix to access an outside telephone
line (if exists).
8.
9.
Here you determine the dialing method used by the automatic dialer built
into the PowerMaster-10 control panel.
10.
11.
or
Select between "Pulse" and "tone (dtmf)".
12.
27:SIREN ON LINE
disable on fail
Pulse
DIAL METHOD
LINE PREFIX
LINE PREFIX
AREA CODE
AREA CODE
1:PSTN/GSM
DEFINE COMM.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMASTER-10 - INSTALLER GUIDE and is the answer not in the manual?

Visonic POWERMASTER-10 - INSTALLER GUIDE Specifications

General IconGeneral
CategorySecurity System
ModelPOWERMASTER-10
Wireless ProtocolPowerG
Backup BatteryYes
User CodesUp to 48 user codes
TypeWireless Alarm System
Partitions3
CommunicationGSM
Wireless Frequency868 MHz
KeypadsUp to 8 keypads
Event Log1000 events
Power SupplyExternal power supply
Backup Battery Voltage7.2V
Operating Temperature-10°C to +50°C
Humidity85% non-condensing
ZonesUp to 30 wireless zones