EasyManuals Logo

WAGNER Prima Sprint Airfluid User Manual

WAGNER Prima Sprint Airfluid
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
38
Prima Sprint.
P_01138
2
1
OPERATING MANUAL
VERSION 07/2009 ORDER NUMBER DOC 2305835
6.2.3 ADJUSTING FLUIDIZATION (60L CONTAINER WITHOUT VIBRATOR TABLE)
Procedure:
1. Open the lid and fi ll the powder container 1
halfway with powder.
2. Switch on the control unit.
3. Set the parameter “vibrator motor control“ on
the control unit to “ON“ to permanently activate
the fl uid air (see operating manual “EPG Sprint
control unit“).
4. Actuate the trigger of the spray gun for a short
time and release it.
5. Adjust the fl uid air at the throttle 2 until
uidization is recognizable..
Hint:
The amount of fl uid air depends on the
characteristics of the powder. Avoid a build up of
powder dust (too much fl uid air) in the powder
container!
6. Close the powder container 1 and check
whether the exhaust air hose is leading in the
direction of the ventilation system of the powder
coating booth.
Hint:
We recommend using a vibrator table when working
with powders that are diffi cult to feed.
SIHI_05058_ENG
WARNING
Dust development!
Danger of poisoning.
Danger due to escaping dust, contamination of device and device
components.
 The powder container may only be filled to the halfway mark,
because fluidizing increases the volume of powder.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER Prima Sprint Airfluid and is the answer not in the manual?

WAGNER Prima Sprint Airfluid Specifications

General IconGeneral
BrandWAGNER
ModelPrima Sprint Airfluid
CategoryPaint Sprayer
LanguageEnglish

Related product manuals