Prima Sprint.
2
1
P_01146
OPERATING MANUAL
VERSION 07/2009 ORDER NUMBER DOC 2305835
6.2.5 ADJUSTING FLUIDIZATION (3L CONTAINER)
Procedure:
1. Open the lid and fi ll the powder container 1
halfway with powder.
2. Switch on the control unit.
3. Set the parameter “vibrator motor control“ on
the control unit to approx. 4 min., so that fl uid air
for this length of time is activated (see operating
manual “EPG Sprint control unit“).
4. Actuate the trigger of the spray gun for a short
time and release it.
5. Adjust the fl uid air at the throttle 2 until
uidization is recognizable.
Hint:
The amount of fl uid air depends on the
characteristics of the powder. Avoid a build up of
powder dust (too much fl uid air) in the powder
container!
6. Close the powder container 1 and check
whether the exhaust air hose is leading in the
direction of the ventilation system of the powder
coating booth.
SIHI_05058_ENG
WARNING
Dust development!
Danger of poisoning.
Danger due to escaping dust, contamination of device and device
components.
 The powder container may only be filled to the halfway mark,
because fluidizing increases the volume of powder.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER Prima Sprint Airfluid and is the answer not in the manual?

WAGNER Prima Sprint Airfluid Specifications

General IconGeneral
BrandWAGNER
ModelPrima Sprint Airfluid
CategoryPaint Sprayer
LanguageEnglish

Related product manuals