Watlow EZ-ZONE
®
PMI Controller 131 Chapter 6 Setup Page
Setup Page
Display
Parameter Name
Description
Range Default
Modbus
Relative Ad-
dress
CIP -
Class
Instance
Attribute
hex (dec)
Pro-
fibus
Index
Param-
eter
ID
Data
Type
and
Access
**
A.hi
A.hi
Alarm (1 to 4)
High Set Point
If Type (Setup
Page, Alarm Menu)
is set to:
Process - set the
process value that
will trigger a high
alarm.
Deviation - set the
span of units from
the closed loop
set point that
will trigger a high
alarm.
-1,999.000 to
9,999.000°F or
units
-1,128.000 to
5,537.000°C
300.0°F
or units
150.0°C
Instance 1
Map 1 Map 2
1480 1880
Offset to
next in-
stance (Map
1) equals
+50
Offset to
next in-
stance (Map
2) equals
+60
0x6D
(109)
1 to 4
1
19 9001 float
RWES
A.LA
A.LA
Alarm (1 to 4)
Latching
Turn latching on or
off. A latched alarm
has to be turned off
by the user.
nLAt Non-Latching
(60)
LAt Latching (49)
Non-
Latching
Instance 1
Map 1 Map 2
1492 1892
Offset to
next in-
stance (Map
1 equals
+50, for Map
2 equals
+60)
0x6D
(109)
1 to 4
7
27 9007 uint
RWES
A.bL
A.bL
Alarm (1 to 4)
Blocking
Select when an
alarm will be
blocked. After start-
up and/or after the
set point changes,
the alarm will be
blocked until the
process value enters
the normal range.
oFF Off (62)
Str Startup (88)
StPt Set Point (85)
both Both (13)
Off Instance 1
Map 1 Map 2
1494 1894
Offset to
next in-
stance (Map
1 equals
+50, for Map
2 equals
+60)
0x6D
(109)
1 to 4
8
28 9008 uint
RWES
* These parameters/prompts are available in these menus with firmware revisions 11.0 and above.
** R: Read, W: Write, E: EEPROM, S: User Set