Table
16.
Operational
Status Byte (Register
Ru
1)
(cont.)
Bit
Position
Significance
14
lOP
Halt. This
bit
is
set
to
1
Wan
error
con-
dition
is
detected
which causes
the
lOP
to
issue a
halt
order
to
the
addressed
I/O
de-
vice.
Error conditions which may
cause
an
lOP
halt
(independent
of the
HTE
flag
within the
I/O
command doubleword)
are:
1.
Bus
check
fault
that
occurs
while
fetch-
i
ng
a command
2.
Control
check
fault
3.
Memory address error
4.
lOP
memory error
5.
lOP
control error
Table
16.
Operati
onal Status Byte (Register
Ru
1)
(cont.)
Bit
Position
14
(cont.)
Significance
Error conditions which may
cause
an
lOP
halt
only if
the
HTE
flag is
coded
with a 1
are:
1.
Bus
check
fault
that
occurs
while
fetch-
ing
data
2.
Transmission memory error
3.
Transmission
data
error
4.
Incorrect
length
condition
occurring
while
the
SIL
flag is
coded
with a
O.
An
lOP
halt
condition
causes the
current
operation
to
terminate
immediately
as
an
II
unusua I end
ll
•
15
This
bit
is
set
to
a 1 if a Write Lock
Violation
(WL
V)
occurs.
Table
17.
Status Response Bits for
I/O
Instructions
Position
and
State
in Register
Ru
1
Device
Status Byte
Operational
Status Byte
Significance
for
Significance
0 1 2
3
4
5
t
6
t
7 8 9
10
11
12 13
14
15
SIO,
HIO,
and
no
for
TDV
1
- - - -
-
- -
- -
-
- - -
-
-
interrupt pendi ng
T
-
0 0
-
-
-
- -
-
-
-
-
- -
-
-
device
ready
-
0 1
-
-
- -
-
-
- - - - - -
-
device
not operational
-
i 0
- -
- -
-
-
-
-
-
-
-
- -
device
unavai
iabie
I
-
1 1
- -
-
- -
-
- -
-
-
-
-
-
device
busy
unique
to
the
-
-
-
0
-
-
- - -
- - - -
- - -
device
manual
device
and
-
-
-
1
-
-
- -
-
-
-
-
-
- - -
device
automatic
the
device
-
-
-
-
1
-
- -
-
-
-
-
-
-
- -
device
unusual end
controller
-
-
-
-
-
0 0
-
-
-
-
-
-
- - -
device
controller
ready
- -
-
-
-
0
1
- -
-
- -
- -
-
-
device
controller
not
operational
-
-
- -
-
1 0
-
- - -
- -
- -
-
device
controller
unavailable
-
-
-
- -
1 1
- -
-
-
- -
-
- -
device
controller
busy
-
- - -
-
-
-
:jI~I:::
-
- -
-
-
-
-
-
reserved
-
- - -
-
-
-
-
1
-
-
- -
- -
-
incorrect
length
-
- -
-
-
-
-
-
-
1
-
- - -
-
-
transmission
data
error
-
-
-
- - -
- - -
-
1
- -
- - -
transmission memory error
-
-
- -
- -
-
-
-
-
-
1
-
-
-
-
memory address error
same as for
SIO,
HIO,
- -
-
-
-
- -
-
-
-
-
-
1
-
- -
lOP
memory error
and
no
-
-
-
-
- - -
- -
-
-
-
-
1
-
-
lOP
control error
I
-
-
- - - - -
-
- -
-
-
-
-
1
-
lOP
halt
-
-
-
-
-
-
-
- -
-
-
-
-
-
-
1 write lock
violation
tThe
significance
of bits 5
and
6 when response is from
an
RMP
is
as
follows:
Bit 5 .
Bit
6
RMP
Function
--
--
0 0
RMP
ready
0 1
RMP
not operational
1 0 reserved
1 1
RMP
busy
Input/Output
Instructions 133

Table of Contents

Other manuals for Xerox 560

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox 560 and is the answer not in the manual?

Xerox 560 Specifications

General IconGeneral
Print Resolution2400 x 2400 dpi
Monthly Duty CycleUp to 300, 000 pages
Duplex PrintingStandard
Operating System CompatibilityWindows, Mac OS, Linux
ConnectivityEthernet, USB
Paper SizeUp to 13 x 19.2 inches
TypeMultifunction Printer

Related product manuals