[Input mode]
L2MS mode
[Description]
Specifies the time interval at which device information for a device downstream of a wireless AP is acquired. Information for
the devices existing downstream the wireless AP is acquired when the time specified by time has elapsed.
If this command is executed with the "no" syntax, the setting returns to the default.
[Note]
If device watch is not operating, device information is not acquired, regardless of the setting of this function.
[Example]
Set the device information acquisition time interval to 3,600 seconds.
SWR2311P(config)#l2ms configuration
SWR2311P(config-l2ms)#l2ms enable
SWR2311P(config-l2ms)#l2ms role master
SWR2311P(config-l2ms)#terminal-watch enable
SWR2311P(config-l2ms)# wireless-terminal-watch interval 3600
4.20.12 Set event monitoring function
[Syntax]
event-watch enable
event-watch disable
no event-watch
[Keyword]
enable : Enable the event monitoring function
disable : Disable the event monitoring function
[Initial value]
event-watch enable
[Input mode]
L2MS mode
[Description]
Sets whether to disable or enable the event monitoring function. If enabled, event information for the L2MS slaves existing on
the network is acquired at regular intervals.
If this command is executed with the "no" syntax, the event monitoring function is enabled.
[Note]
Event monitoring is performed only if L2MS is operating as master.
[Example]
Disable the event monitoring function.
SWR2311P(config)#l2ms configuration
SWR2311P(config-l2ms)#l2ms enable
SWR2311P(config-l2ms)#l2ms role master
SWR2311P(config-l2ms)#event-watch disable
4.20.13 Set event information acquisition time interval
[Syntax]
event-watch interval time
no event-watch interval
[Parameter]
time : <60-1800>
Acquisition time interval (seconds)
[Initial value]
event-watch interval 300