Chapter 3
Configuration
3.1 Manage setting values
The SWR2311P uses the following configurations to manage its settings.
Types of configuration Description
User operations that can be
performed
Running configuration (running-config)
Setting values currently used for
operation. Managed in RAM.
Note / Save to startup configuration
Startup configuration (startup-config)
These are the saved setting values. This
manages 5 configurations in ROM and 1
configuration on an SD card. The data in
ROM to be used is determined using the
startup-config select command.
The single configuration on the SD card
is managed in the "\swr2311p\startup-
config" folder.
Note / Delete / Copy
Default configuration (default-config)
Default setting values. Managed in
ROM.
No operations possible
The start-up flow for the SWR2311P system is as follows.
1. The setting value of the startup-config select command is referenced to determine the startup config that will be used.
If sd is selected by the startup-config select command, and an SD card is not inserted, startup config #0 is selected.
2. If the startup configuration that was selected exists, the data in question is deployed to RAM as a running configuration.
If the startup configuration file that was selected according to the setting values in the startup-config select command does
not exist in ROM, the default configuration is deployed to RAM.
If commands etc. are used to modify the settings while the SWR2311P is running, the modified settings are immediately
reflected in the running configuration. After modifying the running configuration, executing the write or copy command will
update the startup configuration. If you restart without saving the content that was specified or modified, the settings or
modifications are lost. Please be aware of this.
3.2 Default setting values
The default setting values for the SWR2311P are shown in the table below.
•
Default setting values for the entire system
Category Setting item Default value
Terminal settings
Console timeout 600 sec
Number of VTYs 8
Number of lines displayed 24
Password
Login password of no user none
Administrator password none
Password encryption not encrypted
Time management
Time zone JST (UTC + 9.0H)
NTP server none
NTP update cycle once per hour
RMON Behavior enabled
Firmware update Download URL
firmware-update url http://
www.rtpro.yamaha.co.jp/firmware/
revision-up/swr2311p.bin
Command Reference | Configuration | 23