2.3 List of Fault, Minor Fault, Alarm, and Error Codes
36 YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
Display (Hex.) Name ALM LED Type Ref.
oFA30 - oFA43 (0131 - 013E) Communication Option Card Connection Error (CN5) Illuminated Fault 50 - 51
oH (0003) Heatsink Overheat Flashing Alarm 66
oH (0009) Heatsink Overheat Illuminated Fault 51
oH1 (000A) Heatsink Overheat Illuminated Fault 52
oH2 (0004) External Overheat (H1-XX=B) Flashing Alarm 66
oH3 (001D) Motor Overheat (PTC Input) Illuminated Fault 52
oH3 (0022) Motor Overheat (PTC Input) Flashing Alarm 66
oH4 (0020) Motor Overheat Fault (PTC Input) Illuminated Fault 52
oL1 (000B) Motor Overload Illuminated Fault 52
oL2 (000C) Drive Overload Illuminated Fault 53
oL3 (0005) Overtorque 1 Flashing Alarm 66
oL3 (000D) Overtorque Detection 1 Illuminated Fault 54
oL4 (0006) Overtorque 2 Flashing Alarm 67
oL4 (000E) Overtorque Detection 2 Illuminated Fault 54
oL5 (003D) Mechanical Weakening Detection 1 Flashing Alarm 67
oL5 (0044) Mechanical Weakening Detection 1 Illuminated Fault 54
oL7 (002B) High Slip Braking Overload Illuminated Fault 54
oPE01 Drive Capacity Setting Fault Flashing Parameter Setting Error 70
oPE02 Parameter Range Setting Error Flashing Parameter Setting Error 70
oPE03 Multi-Function Input Setting Err Flashing Parameter Setting Error 70
oPE05 Run Cmd/Freq Ref Source Sel Err Flashing Parameter Setting Error 71
oPE07 Analog Input Selection Error Flashing Parameter Setting Error 72
oPE08 Parameter Selection Error Flashing Parameter Setting Error 72
oPE09 PID Control Selection Fault Flashing Parameter Setting Error 73
oPE10 V/f Data Setting Error Flashing Parameter Setting Error 73
oPE11 Carrier Frequency Setting Error Flashing Parameter Setting Error 73
oPE13 Pulse Monitor Selection Error Flashing Parameter Setting Error 73
oPE16 Energy Saving Constants Error Flashing Parameter Setting Error 73
oPE33 Digital Output Selection Error Flashing Parameter Setting Error 74
oPr (001E) Keypad Connection Fault Illuminated Fault 54
oS (0010) Overspeed Flashing Alarm 67
oS (0018) Overspeed Illuminated Fault 67
ov (0002) Overvoltage Flashing Alarm 67
ov (0008) Overvoltage Illuminated Fault 55
ovEr Too Many Parameters Changed - Not an alarm. 67
PASS Modbus Communication Test Flashing Not an alarm. 67
PE1 (0047) PLC Faults Illuminated Fault 56
PE2 (0048) PLC Faults Illuminated Fault 56
PF (0047) Input Phase Loss Flashing Alarm 67
PF (001B) Input Phase Loss Illuminated Fault 56
PWEr DWEZ Password Mismatch - Backup Function Runtime Error 79
rdEr Error Reading Data - Backup Function Runtime Error 80
rF (004E) Braking Resistor Fault Illuminated Fault 56