7 CANopen Lift
72 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum
641F (Hex): Position Conversion
Index (Hex) Sub Content Access Range
Initial Value
(Hex)
641F 0 Number of Entries RO 2 2
641F 1 Number of Position Units RW UNS32 0
641F 2 Total Length in Millimeter RW UNS32 0
This object contains the conversion coefficients to convert the target position from the drive controller and the
position value from the position device into millimeters (mm).
Note:
To enable correct operation, this object must be configured by the drive controller.
6420 (Hex): Target Position
Index (Hex) Sub Content Access Range
Initial Value
(Hex)
6420 0 Target Position RW SINT32 0
This object indicates the commanded position that the drive should move to in profile position mode. The value of
this object must be set in terms of shaft encoder increments.
Note:
When you want to command a new position setpoint, you must use the control word bit 4 New setpoint.
6421 (Hex): Position Range Limit
Index (Hex) Sub Content Access Range
Initial Value
(Hex)
6421 0 Number of Entries RO UNS8 2
6421 1 Min Position Range Limit RW SINT32 0
6421 2 Max Position Range Limit RW SINT32 0
This object indicates the configured maximum and minimum position range limits. This object limits the
numerical range of the input value. A position command which exceeds these limits is ignored. The "setpoint
acknowledge" bit in the status word is not set. The values are given in terms of shaft encoder increments. Make
sure the values meet the condition Min Position Range Limit < Max Position Range Limit.
6423 (Hex): Profile Velocity
Index (Hex) Sub Content Access Range
Initial Value
(Hex)
6423 0 Profile Velocity RW UNS32 0
This object sets an upper limit for the speed which is used in Profile Position Mode. The maximum speed in a
Profile Position Mode travel may fall below the set value but may not exceed it. The value is given in multiples of
1 mm/s.
Note:
The speed is limited to the value defined with parameter E1-04.
6430 (Hex): Target Velocity
Index (Hex) Sub Content Access Range
Initial Value
(Hex)
6430 0 Target Velocity RW SINT32 0
This object indicates the configured target velocity, and is used in Profile Velocity mode. The value is given in
multiples of 1 mm/s.
Note:
The speed is limited to the value defined with parameter E1-04.
6433 (Hex): Velocity Actual Value
Index (Hex) Sub Content Access Range
Initial Value
(Hex)
6433 0 Velocity Actual Value RO SINT32 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA L1000A CIMR-LC F Series and is the answer not in the manual?

YASKAWA L1000A CIMR-LC F Series Specifications

General IconGeneral
Enclosure RatingIP20
Frequency Range50/60Hz
Protection FeaturesOvercurrent, Overvoltage, Undervoltage
Communication InterfaceModbus
Storage Temperature-20°C to +60°C (-4°F to +140°F)
Humidity5% to 95% (non-condensing)
Cooling MethodFan Cooled