4.11 Fan and Pump Application Presets
The following sections list the parameters affected by the different Application Presets.
u
A1-03 = 8008: Pump
Table 4.31 Pump Application Parameters
Parameter Name Page
A1-06 Application Preset Selection (monitor only) 90
b1-01 Frequency Reference Selection 92
b1-02 Run Command Selection 93
b1-03 Stopping Method Selection 94
b1-04 Reverse Operation Selection 128
C1-01 Acceleration Time 1 99
C1-02 Deceleration Time 1 99
d1-01 Frequency Reference 1 100
E2-01 Motor Rated Current 106
L2-01 Momentary Power Loss Operation Selection 130
L5-01 Number of Auto Restart Attempts 131
L5-04 Fault Reset Interval Time 131
o1-06 User Monitor Selection Mode 132
o1-07 Second Line Monitor Selection 132
o1-08 Third Line Monitor Selection 132
u
A1-03 = 8009: Pump w/ PI
Table 4.32 Pump w/ PI Application Parameters
Parameter Name Page
A1-06 Application Preset Selection (monitor only) 90
b1-02 Run Command Selection 93
b1-03 Stopping Method Selection 94
b1-04 Reverse Operation Selection 128
b5-19 PID Setpoint Value 128
b5-38 PID Setpoint User Display 129
b5-39 PID Setpoint Display Digits 129
b5-46 PID Unit Selection 129
b5-90 EZ Sleep Unit 129
b5-91 EZ Minimum Speed 129
b5-92 EZ Sleep Level 130
b5-94 EZ Wake-up Level 130
C1-01 Acceleration Time 1 99
C1-02 Deceleration Time 1 99
E2-01 Motor Rated Current 106
H3-09 Terminal A2 Signal Level Selection 112
L5-01 Number of Auto Restart Attempts 131
L5-04 Fault Reset Interval Time 131
o1-07 Second Line Monitor Selection 132
o1-08 Third Line Monitor Selection 132
4.11 Fan and Pump Application Presets
YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide
125
4
Start-Up Programming &
Operation

Table of Contents

Other manuals for YASKAWA P1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA P1000 and is the answer not in the manual?

YASKAWA P1000 Specifications

General IconGeneral
Operating Temperature-10°C to +50°C (14°F to 122°F)
Cooling MethodFan Cooled
Output Voltage0-Input Voltage
Output Frequency0-400 Hz
Frequency Range0.1-400 Hz
Power Rating0.4 kW to 630 kW
Control MethodV/f Control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit, Ground Fault
Protection FeaturesElectronic Thermal Overload Protection
CommunicationModbus RTU
Communication InterfaceRS-485
Humidity5% to 95% (non-condensing)
AltitudeUp to 1000m (3280ft) without derating
Enclosure RatingIP20

Related product manuals