USING THE DIGITAL OPERATOR
4.2.1 Operation in Alarm Trace-back Modecont.
184
2) Using the Alarm Trace-back Mode
Follow the procedure below to determine which alarms occurred previously.
For JUSP-OP02A-1
1) Press
DSPL
SET
to select the alarm trace-
back mode.
2) Press the
and keys to scroll the
alarm sequence numbers up and down
and display information on previous
alarms. The higher the left-hand digit
(alarm sequence number), the older the
alarm data.
For JUSP-OP03A
1) Press
MODE/SET
to select the alarm trace-
back mode.
2) Press the
UP
and
DOWN
keys to scroll the
alarm sequence numbers up and down
and display information on previous
alarms. The higher the left-hand digit
(alarm sequence number), the older the
alarm data.
4
JUSP-OP02A-1
Alarm Trace-back Mode
Older
Newer
JUSP-OP03A
Alarm Trace-back Mode
Older
Newer

Table of Contents