REVIEWING THE FULL-CLOSED LOOP SPECIFICATIONS
494
* Number of Full–closed Pulses = Cn–2A =
4
0.01×10
25×6
=
4 × 25 × 6
0.01 × 10
= 6000Prev
. * Memory switch Cn-02 Bit B =1
Conditions except above are the same as those of position control at full-closed speci-
fications.
Reviewing the above data, full-closed loop can be applicable under the above condi-
tions.