Chapter 9 VDSL Setup
VES1724-56 User’s Guide
123
The device sends an alarm trap and generates a syslog entry when the thresholds of the alarm
profile are exceeded.
Figure 66 VDSL Line Alarm Profile Setup
The following table describes the labels in this screen.
Table 44 VDSL Line Alarm Profile Setup
LABEL DESCRIPTION
Name Enter a descriptive name for identification purposes.
VTUC Configure the thresholds in this column for the Switch (VTUC).
VTUR Configure the thresholds in this column for CPE devices (VTUR).
15 Minute FECS
Threshold
Enter the number of Forward Error Correction Seconds (FECS) that are permitted to occur
within 15 minutes.
15 Minute ES
Threshold
Enter the number of Errored Seconds (ES) that are permitted to occur within 15 minutes.
15 Minute SES
Threshold
Enter the number of Severely Errored Seconds (SES) that are permitted to occur within 15
minutes.
15 Minute LOSS
Threshold
Enter the number of Loss Of Signals Seconds (LOSS) that are permitted to occur within 15
minutes.
15 Minute UAS
Threshold
Enter the number of UnAvailable Seconds (UAS) that are permitted to occur within 15
minutes.
15 Minute LOFS
Threshold
Enter the number of Loss Of Framing Seconds (LOFS) that are permitted to occur within
15 minutes.
15 Minute LPRS
Threshold
Enter the number of times a Loss of PoweR Seconds (LPRS) is permitted to occur within 15
minutes.
15 Minute
FailedFullInt
Threshold
Enter the number of times a full initialization is allowed to fail within 15 minutes.