Chapter 37 Access Control
VES1724-56 User’s Guide
341
mactable MacTableFullEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2.1 This trap is sent when more than 99% of
the MAC table is used.
MacTableFullEventClear or 1.3.6.1.4.1.890.1.5.12.46.45.2.2 This trap is sent when less than 95% of the
MAC table is used.
rmon RmonRisingAlarm 1.3.6.1.2.1.16.0.1 This trap is sent when a variable goes over
the RMON "rising" threshold.
RmonFallingAlarm 1.3.6.1.2.1.16.0.2 This trap is sent when the variable falls
below the RMON "falling" threshold.
Table 160 SNMP Switch Traps (continued)
OPTION OBJECT LABEL OBJECT ID DESCRIPTION
Table 161 SNMP VDSL Traps
OPTION OBJECT LABEL OBJECT ID DESCRIPTION
alarmprofile xdsl2LinePerfFECSThresh
Xtuc
1.3.6.1.2.1.10.251.0.1 This trap is sent when the Switch detects
that the number of FEC seconds exceeds
the threshold.
xdsl2LinePerfFECSThresh
Xtur
1.3.6.1.2.1.10.251.0.2 This trap is sent when the number of FEC
seconds in CPE side exceeds the threshold.
xdsl2LinePerfESThreshXt
uc
1.3.6.1.2.1.10.251.0.3 This trap is sent when the Switch detects
that the number of errored seconds
exceeds the threshold.
xdsl2LinePerfESThreshXt
ur
1.3.6.1.2.1.10.251.0.4 This trap is sent when the number of
errored seconds in CPE side exceeds the
threshold.
xdsl2LinePerfSESThresh
Xtuc
1.3.6.1.2.1.10.251.0.5 This trap is sent when the Switch detects
that the number of severely errored
seconds exceeds the threshold.
xdsl2LinePerfSESThresh
Xtur
1.3.6.1.2.1.10.251.0.6 This trap is sent when the number of
severely errored seconds in CPE side
exceeds the threshold.
xdsl2LinePerfLOSSThres
hXtuc
1.3.6.1.2.1.10.251.0.7 This trap is sent when the Switch detects
that the number of LOS seconds exceeds
the threshold.
xdsl2LinePerfLOSSThres
hXtur
1.3.6.1.2.1.10.251.0.8 This trap is sent when the number of LOS
seconds in CPE side exceeds the threshold.
xdsl2LinePerfUASThresh
Xtuc
1.3.6.1.2.1.10.251.0.9 This trap is sent when the Switch detects
that the number of unavailable seconds
exceeds the threshold.
xdsl2LinePerfUASThresh
Xtur
1.3.6.1.2.1.10.251.0.10 This trap is sent when the number of
unavailable seconds in CPE side exceeds
the threshold.
xdsl2LinePerfCodingViola
tionsThreshXtuc
1.3.6.1.2.1.10.251.0.11 This trap is sent when the Switch detects
that the number of coding violations
exceeds the threshold..
xdsl2LinePerfCodingViola
tionsThreshXtur
1.3.6.1.2.1.10.251.0.12 This trap is sent when the number of
coding violations in CPE side exceeds the
threshold.
xdsl2LinePerfCorrectedT
hreshXtuc
1.3.6.1.2.1.10.251.0.13 This trap is sent when the Switch detects
that the number of corrected blocks (FEC
events) exceeds the threshold.