EasyManua.ls Logo

ZyXEL Communications VES1724-56 - Page 362

ZyXEL Communications VES1724-56
414 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 40 Loop Diagnostic
VES1724-56 User’s Guide
362
After the DELT test completes, a summary report displays at the bottom of this screen. This is an
example.
Figure 234 Dual-End Loop Test Report
The following table describes the test report labels in this screen.
Table 172 Dual-End Loop Test Report
LABEL DESCRIPTION
Attainable net
data rate
The is the maximum upstream/downstream data rate for this line.
Actual
Aggregate Tx
Power
This is the total amount of upstream/downstream output power for this line.
Band Status The fields in this section display the status for upstream bands 0, 1, 2, 3, 4 (U0, U1, U2,
U3, U4) and downstream bands 1, 2, 3, 4 (D1, D2, D3, D4).
LATN This field displays the line attenuation situation in each band. NA displays when the band is
not used.
SATN This field displays the signal attenuation situation in each band. NA displays when the band
is not used.
SNRM This field displays signal-to-noise ratio margin in each band. NA displays when the band is
not used.
Sub-Carrier
Status
This section allows you to select the criteria and display you the statistics in a raw data list or
in a graph.
Items Select Hlog-ps (Channel Transfer Function per sub-carrier) to see the line’s capability
against attenuation.
Select QLN-ps (Quiet Line Noise per sub-carrier) to see the line’s noise level.
Select SNR-ps (Signal-to-Noise-Ratio per sub-carrier) to see the line’s signal strength level
by calculating the ratio between the received signal power and the received noise power for
that sub-carrier.
Select Hlin-ps to see the lines capability against attenuation.
Direction Select Downstream or Upstream for the direction.

Table of Contents

Related product manuals