4. With a drip container and paper towels ready, pull the bottom hose loose from the connector (3) and position the hose over
the container (4).
Hose connector
Drip
Container
3 4
Remove hose from connector
Remove cover with athead screwdriver
Squeeze two tabs together to release hose. Use latch to turn mechanism.
Turn mechanism to remove hose
Open cover to access inside
Place hose over drip container to
catch any excess print material
Have paper towels available to wipe
up excess print material
5. Using a pair of wire cutters, cut all zip ties which are securing the hose to the MDM.
6. Unfasten the peristaltic pump cover using a athead screwdriver (5). Open the panel to gain access to the internal
mechanism (6).
5 6
7
8
7. While squeezing the two tabs together on the pump mechanism (7), use the latch to rotate the mechanism until the hose is
freed (8).
Tabs
Latch