Chapter 8. Configuring Units
148 3ware Serial ATA RAID Controller User Guide
To enable or disable queuing for a unit through 3DM
1 Choose
Management > Controller Settings from the menu bar in 3DM.
2In the
Unit Policies section of the Controller Settings Page, enable
queuing by checking the box under “Queuing” for the designated unit;
disable it by unchecking the box.
The page refreshes, and a message at the top confirms the change you
have made.
To enable or disable queuing for a unit through 3BM
1 At the main 3BM screen, select the unit by highlighting it and pressing
Enter.
An asterisk appears in the left-most column to indicate that it is selected.
2 Tab to the
Maintain Unit button and press Enter.
3 On the pop-up menu, select
Configure and press Enter.
4In the
Configure Disk Array screen, Tab to the field Drive Queuing
Mode
.
5 Press
Enter to display the choices, use the arrow keys to select the setting
you want (Enabled or Disabled), and press
Enter again to choose it.
6 Tab to the OK button and press Enter to select it.
You return to the main 3BM screen.
7 When you are finished making changes, press
F8 to save them and exit
3BM.