EasyManua.ls Logo

3Ware 9550SX-4LP - Adding a Drive through 3 DM

3Ware 9550SX-4LP
272 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8. Configuring Units
168 3ware Serial ATA RAID Controller User Guide
Adding a Drive through 3DM
Note: If you have a 9550SX or 9590SE controller, when you add a
drive to your system and connect it to the controller, it is
automatically detected and listed in 3DM and the CLI.
If you have a 9500S or 7/8000 controller, follow the steps below to
make a new drive available.
If you have a hot-swap carrier, you can add a drive to your system and make it
available through 3DM without powering down the system.
Without hot swap carriers, you should not add a drive via 3DM. Instead,
power down the system and add the applicable drives.
Warning: Physically adding a drive without a hotswap carrier and
without powering down your system can result in a system hang or
may even damage the system and the drive.
To add a drive through 3DM when you have hot-swap carriers
1 Connect the drive physically to the controller.
2 In 3DM, choose
Management > Maintenance.
3 On the Maintenance Page, click Rescan Controller.
The drive will appear in the list of available drives. You can now use it in
a new RAID configuration, or as a replacement drive in the event that
another drive degrades.
If you want to use this drive as a spare, see “Creating a Hot Spare” on
page 139.

Table of Contents