Setting Unit Policies
www.3ware.com 145
6 Tab to the OK button and press Enter to select it.
You return to the main 3BM screen.
7 When you are finished making changes, press
F8 to save them and exit
3BM.
Setting Auto-Verify for a Unit
For 9000-series controllers, the auto-verify policy causes verify tasks to be
performed automatically, whenever the controller firmware algorithms
determine that a verify task is needed. This feature is designed to make
verification of units easier. When you enable this for a unit, the controller will
run verify tasks as they are required.
If there is no schedule set up for verify tasks, then the controller firmware can
initiate a verify task at any time. If a verify time window is scheduled, then
the controller will not start a verify task for that unit outside the time window,
and may or may not start a verify task for that unit within the time window,
depending on whether one is needed.
If Auto-verify is not set and there is no schedule for verify tasks, you must
manually specify when you want to run a verify, on the 3DM
Management
page. If a schedule is set for verify, then the verify that you manually start will
only run during the scheduled time.
You can set this policy while creating a unit through 3DM or CLI, and you
can change it for existing units.
To set the auto-verify policy for an existing unit
1 Choose
Management > Controller Settings from the menu bar in 3DM.
2In the
Unit Policies section of the Controller Settings Page, check the
Auto Verify box for the unit for which you want to set it. (To disable this
policy, uncheck the box.)
The page refreshes, and a message at the top confirms the change you
have made (Figure 63).