Chapter 11. Troubleshooting
240 3ware Serial ATA RAID Controller User Guide
053h Battery capacity test is overdue
The recommended time interval for running the battery capacity test is once
every 4 weeks. If a battery capacity test has not been completed in the last 4
weeks this AEN will be sent to the host, and once every week thereafter.
055h Battery charging started
This AEN is posted when the Battery Backup Unit starts a battery charge
cycle.
056h Battery charging completed
This AEN is posted when the Battery Backup Unit completes a battery charge
cycle.
057h Battery charging fault
This AEN is posted when the charger of the Battery Backup Unit has detected
a battery fault during a charge cycle. The Battery Backup Unit becomes not
ready and is unable to backup the 3ware RAID controller.
058h Battery capacity is below warning level
The measured capacity of the battery is below the warning level. When this
occurs the Battery Backup Unit is still able to backup the 3ware RAID
controller but it signals that the battery pack should be replaced soon.
059h Battery capacity is below error level
The measured capacity of the battery is below the error level. When this
occurs the Battery Backup Unit becomes not ready and is unable to backup
the 3ware RAID controller. The user must replace the battery pack.
05Ah Battery is present
This AEN is posted to the host when the Battery Backup Unit detects that a
battery pack has been connected.
05Bh Battery is not present
This AEN is posted to the host when the Battery Backup Unit detects that the
battery pack has been removed.