Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
- / uint16Shows the status of the adaptive program.
See section Adaptive programming (page 69).
Adaptive program
status
7.30
1 = Adaptive program initializedInitializedb0
1 = Adaptive program is being editedEditingb1
1 = Editing of adaptive program finishedEdit doneb2
1 = Adaptive program runningRunningb3
Reservedb4…13
ReservedState changingb14
1 = Error in adaptive programFaultedb15
1 = 10000h…FFFFh
- / real32
(Only visible with option +N8010 [application
programmability])
Displays the peak loading of the microprocessor caused
by the application program. This parameter can, for
example, be used to check the effect of a given
application program functionality on the CPU load.
The value is in percent of an internal quota.
Can be reset from the control panel by keeping Reset
depressed for over 3 seconds.
IEC application Cpu
usage peak
7.40
10 = 1 % / 10 = 1 %Peak microprocessor loading caused by application
program.
0.0 ... 100.0 %
- / real32
(Only visible with option +N8010 [application
programmability])
Displays the average loading of the microprocessor
caused by the application program. The value is in
percent of an internal quota.
IEC application Cpu
load average
7.41
10 = 1 % / 10 = 1 %Average microprocessor loading caused by application
program.
0.0 ... 100.0 %
- / uint16Displays the type of module detected in slot 1 of the
drive control unit.
Slot 1 option module7.51
0No module detected.
1Type of module detected.
- / uint16Displays the type of module detected in slot 2 of the
drive control unit.
Slot 2 option module7.52
1 = 1 / 1 = 10...65535
0No module detected.
1Type of module detected.
- / uint16Displays the type of module detected in slot 3 of the
drive control unit.
Slot 3 option module7.53
1 = 1 / 1 = 10...65535
0No module detected.
1Type of module detected.
206 Parameters