Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Configuration of standard analog outputs.Standard AO13
- / real32Displays the value of AO1 in mA.
This parameter is read-only.
AO1 actual value13.11
1000 = 1 mA / 1000 =
1 mA
Value of AO1.0.000 ... 22.000 mA
Motor speed used /
uint32
Selects a signal to be connected to analog output AO1.
Alternatively, sets the output to excitation mode to
feed a constant current to a temperature sensor.
AO1 source13.12
0NoneZero
11.1 Motor speed used (page 174).Motor speed used
31.6 Output frequency (page 174).Output frequency
41.7 Motor current (page 174).Motor current
61.10 Motor torque (page 174).Motor torque
71.11 DC voltage (page 175).DC voltage
81.14 Output power (page 175).Power inu out
1023.1 Speed ref ramp input (page 311).Speed ref ramp in
1123.2 Speed ref ramp output (page 311).Speed ref ramp out
1224.1 Used speed reference (page 318).Speed ref used
1326.2 Torque reference used (page 338).Torq ref used
1428.2 Frequency ref ramp output (page 347).Freq ref used
1640.1 Process PID output actual (page 420).Process PID out
1740.2 Process PID feedback actual (page 420).Process PID fbk
1840.3 Process PID setpoint actual (page 420).Process PID act
1940.4 Process PID deviation actual (page 420).Process PID dev
See Terms and abbreviations (page 169).Other [value]
20The output is used to feed an excitation current to 1…3
Pt100 sensors. See section Motor thermal
protection (page 128).
Force Pt100
excitation
21The output is used to feed an excitation current to a
KTY84 sensor. See section Motor thermal
protection (page 128).
Force KTY84
excitation
22The output is used to feed an excitation current to 1…3
PTC sensors. See section Motor thermal
protection (page 128).
Force PTC excitation
23The output is used to feed an excitation current to 1…3
Pt1000 sensors. See section Motor thermal
protection (page 128).
Force Pt1000
excitation
3713.91 AO1 data storage (page 235).AO1 data storage
3813.92 AO2 data storage (page 235).AO2 data storage
230 Parameters