Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
- / real32Measured DC link voltage.DC voltage1.11
10 = 1 V / 100 = 1 VDC link voltage.0.00 ... 2000.00 V
- / real32Calculated motor voltage in V AC.Output voltage1.13
1 = 1 V / 1 = 1 VMotor voltage.0...2000 V
- / real32Drive output power. The unit is selected by parameter
96.16 Unit selection. A filter time constant for this signal
can be defined by parameter 46.14 Filter time power
out.
Output power1.14
- / -Output power. For scaling, see parameter 46.4.-32768.00 ...
32767.00 kW
- / real32Shows the value of 1.14 Output power in percent of the
nominal power of the motor.
Output power % of
motor nom
1.15
10 = 1 % / 100 = 1 %Output power.-300.00 ... 300.00 %
- / real32Estimated mechanical power at motor shaft. The unit
is selected by parameter 96.16 Unit selection. A filter
time constant for this signal can be defined by
parameter 46.14 Filter time power out.
Motor shaft power1.17
1 = 1 kW or hp / 100 =
1 kW or hp
Motor shaft power.-32768.00 ...
32767.00 kW or hp
- / int16Amount of energy that has passed through the drive
(towards the motor) in full gigawatt-hours. The
minimum value is zero.
Inverter GWh
motoring
1.18
1 = 1 GWh / 1 = 1 GWhMotoring energy in GWh.0...32767 GWh
- / int16Amount of energy that has passed through the drive
(towards the motor) in full megawatt-hours. Whenever
the counter rolls over, 1.18 Inverter GWh motoring is
incremented. The minimum value is zero.
Inverter MWh
motoring
1.19
1 = 1 MWh / 1 = 1 MWhMotoring energy in MWh.0...1000 MWh
- / real32Amount of energy that has passed through the drive
(towards the motor) in full kilowatt-hours. Whenever
the counter rolls over, 1.19 Inverter MWh motoring is
incremented. The minimum value is zero.
Inverter kWh
motoring
1.20
10 = 1 kWh / 1 = 1 kWhMotoring energy in kWh.0...1000 kWh
- / real32Measured U-phase current.U-phase current1.21
- / -U-phase current. For scaling, see parameter 46.5.-30000.00 ...
30000.00 A
- / real32Measured V-phase current.V-phase current1.22
- / -V-phase current. For scaling, see parameter 46.5.-30000.00 ...
30000.00 A
- / real32Measured W-phase current.W-phase current1.23
- / -W-phase current. For scaling, see parameter 46.5.-30000.00 ...
30000.00 A
- / real32Used flux reference in percent of nominal flux of motor.Flux actual %1.24
1 = 1 % / 1 = 1 %Flux reference.0...200 %
Parameters 175