Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
ESP signals to monitor the pump.ESP signals9
- / unit16Displays the current state of the ESP application
functions.
ESP status word9.1
Drive is following the ESP program reference.Production stateb0
Restart delay timer is active.Restart delay actb1
Backspin speed observer routine is active.Backspin observer
act
b2
Reservedb3…4
Kick-start starting routine is active.Kick-start actb5
Current-pulse starting routine is active.Current pulse actb6
Underload condition is active.Underload actb7
Overload condition is active.Overload actb8
Reservedb9…10
Voltage or current boost is active.Current boost/IR
comp. act
b11
Pump cleaning operation is active.Cleaning actb12
Reservedb13…14
Time control is active.Time control actb15
1 = 1 = 10000h…FFFFh
- / unit16Displays the status of ESP application functions.ESP control status9.3
Reservedb0
Restart delay function is enabled.Restart delayb1
Backspin speed observer function enabled.Backspin speed
observer
b2
Reservedb3
Acceleration assistance function enabledAcceleration
assistance
b4
Kick-start function enabled.Kick-startb5
Current-pulse start function enabled.Current pulse startb6
Underload protection function enabled.Underload
protecdtion
b7
Overload protection function enabled.Overload protectionb8
Energy optimizer function enabled.Energy optimizerb9
U/f function enabled.U/f voltage curveb10
IR-compensation function enabled.IR-compensationb11
Pump cleaning function enabled.Pump cleaningb12
Reservedb13
Auto mode function enabled.Auto mode enableb14
Time control function enabled.Time controlb15