Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Not selected / uint32With a speed-controlled follower, selects the source
for enabling/disabling the load share function.
See section Load share function with a speed-controlled
follower (page 74).
0 = Disabled
1 = Enabled
Follower speed
correction enable
23.40
00Not selected
11Selected
2Digital input DI1 (10.2 DI delayed status, bit 0).DI1
3Digital input DI2 (10.2 DI delayed status, bit 1).DI2
4Digital input DI3 (10.2 DI delayed status, bit 2).DI3
5Digital input DI4 (10.2 DI delayed status, bit 3).DI4
6Digital input DI5 (10.2 DI delayed status, bit 4).DI5
7Digital input DI6 (10.2 DI delayed status, bit 5).DI6
10Digital input/output DIO1 (11.2 DIO delayed status, bit
0).
DIO1
11Digital input/output DIO2 (11.2 DIO delayed status, bit
1).
DIO2
See Terms and abbreviations (page 169).Other [bit]
1.00 % / real32Adjusts the gain of the speed correction term in a
speed-controlled follower. In effect, defines how
accurately the follower follows the master torque. A
greater value results in a more accurate performance.
See section Load share function with a speed-controlled
follower (page 74).
Follower speed
correction gain
23.41
1 = 1 % / 100 = 1 %Speed correction term adjustment.0.00 ... 100.00 %
MF ref 2 / uint32Selects the source of the torque reference for the load
share function. See section Load share function with
a speed-controlled follower (page 74).
Follower speed corr
torq source
23.42
0None.NULL
13.14 M/F or D2D ref2 (page 180).MF ref 2
See Terms and abbreviations (page 169).Other [value]
Parameters 317