Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Underload protection is enabled.Underload enabledb0
Parameter 79.12 Underload supervision signal is lower
than 79.80 Underload actual limit and the delay is
counting.
Underload delayb1
Underload condition response is triggered.Underload actb2
Underload recovery sequence is active. Works only if
79.19 Underload event reactionis URT Recovery -
Warning or URT Recovery - Fault.
Underload recovery
act
b3
Speed boost stage of the recovery sequence is active.Underload speed
boost act
b4
Speed drop stage of the recovery sequence is active.Underload speed
drop act
b5
Underload warning event is active.Underload warningb6
Underload fault event is active.Underload faultb7
Overload protection is enabled.Overload enabledb8
Parameter 79.42 Overload supervision signal is greater
than 79.81 Underload trip count down and delay is
counting.
Overload delayb9
Overload condition response is triggered.Overload actb10
Overload recovery speed sequence is active.Overload recovery
speed
b11
Overload warning event is active.Overload warningb12
Enables pump cleaning function.Overload faultb13
Reservedb14...15
1 = 10000h…FFFFh
Parameters 545