Group 20 LIMITS
Definition of drive operation limits.
20
20 LIMITS
Firmware block:
LIMITS
(20)
Adjusts the drive speed, current and
torque limits, selects the source for
the positive/negative speed reference
enable command and enables the
thermal current limitation.
20.01 MAXIMUM SPEED FW block: LIMITS (see above).
Defines the allowed maximum speed. See also parameter 22.08 SPEED TRIPMARGIN.
0…30000 rpm Allowed maximum speed.
20.02 MINIMUM SPEED FW block: LIMITS (see above).
Defines the allowed minimum speed. See also parameter 22.08 SPEED TRIPMARGIN.
-30000…0 rpm Allowed minimum speed.
LIMITS
27
TLF 10 2 msec (5)
20.01 MAXIMUM SPEED
[ 1500 rpm ]
20.02 MINIMUM SPEED
[ -1 500 r pm ]
< 20.03 POS SPEED ENA
[ TRUE ]
< 20.04 NEG SPEED ENA
[ TRUE ]
20.05 MAXIMUM CURRENT
[ 0.00 A ]
20.06 MAXIMUM TORQUE
[ 300.0 % ]
20.07 MINIMUM TORQUE
[ -300.0 % ]