EasyManua.ls Logo

ABB ACSM1 - Ctud

ABB ACSM1
448 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Standard function blocks
321
Inputs Counter input (CU): Boolean
Reset input (R): Boolean
Preset input (PV): DINT
Outputs Status output (Q): Boolean
Counter output (CV): DINT
CTUD
(10051)
Illustration
Execution time 1.40 µs
CTUD
97
TLA1 1 msec (1)
>CU
>CD
R
LD
PV
CV
CV(97)
QU
QU(97)
QD
QD(97)

Table of Contents

Other manuals for ABB ACSM1

Related product manuals