Parameter data
253
Parameter groups 10…99
Index Parameter Type Range Unit FbEq Update
time
Data
len.
Def PT Save
PF
Page
no.
10 START/STOP
10.01 EXT1 START FUNC enum 0…6 - - 2 ms 16 1 WPD 104
10.02 EXT1 START IN1 Bit pointer - 2 ms 32 P.02.01.00 WPD 105
10.03 EXT1 START IN2 Bit pointer - 2 ms 32 C.False WPD 105
10.04 EXT2 START FUNC enum 0…6 - - 2 ms 16 1 WPD 105
10.05 EXT2 START IN1 Bit pointer - 2 ms 32 P.02.01.00 WPD 106
10.06 EXT2 START IN2 Bit pointer - 2 ms 32 C.False WPD 106
10.07 JOG1 START Bit pointer - 2 ms 32 C.False WPD 106
10.08 FAULT RESET SEL Bit pointer - 2 ms 32 P.02.01.02 106
10.09 RUN ENABLE Bit pointer - 2 ms 32 C.True WPD 106
10.10 EM STOP OFF3 Bit pointer - 2 ms 32 C.True WPD 106
10.11 EM STOP OFF1 Bit pointer - 2 ms 32 C.True WPD 107
10.12 START INHIBIT enum 0…1 - 1 = 1 2 ms 16 0 107
10.13 FB CW USED Val pointer - 2 ms 32 P.02.12 WPD 107
10.14 JOG2 START Bit pointer - 2 ms 32 C.False WPD 107
10.15 JOG ENABLE Bit pointer - 2 ms 32 C.False WPD 107
10.16 D2D CW USED Val pointer - 2 ms 32 P.02.17 WPD 107
10.17 START ENABLE Bit pointer - 2 ms 32 C.True WPD 108
11 START/STOP MODE
11.01 START MODE enum 0…2 - 1 = 1 - 16 1 WPD 109
11.02 DC MAGN TIME UINT32 0…10000 ms 1 = 1 - 16 500 WPD 110
11.03 STOP MODE enum 1…2 - 1 = 1 2 ms 16 2 110
11.04 DC HOLD SPEED REAL 0…1000 rpm 1 = 10 2 ms 16 5 110
11.05 DC HOLD CUR REF UINT32 0…100 % 1 = 1 2 ms 16 30 110
11.06 DC HOLD enum 0…1 - 1 = 1 2 ms 16 0 111
11.07 AUTOPHASING
MODE
enum 0…2 - 1 = 1 - 16 1 111
12 DIGITAL IO
12.01 DIO1 CONF enum 0…1 - 1 = 1 10 ms 16 0 112
12.02 DIO2 CONF enum 0…2 - 1 = 1 10 ms 16 0 113
12.03 DIO3 CONF enum 0…3 - 1 = 1 10 ms 16 0 113
12.04 DIO1 OUT PTR Bit pointer - 10 ms 32 P.06.02.02 113
12.05 DIO2 OUT PTR Bit pointer - 10 ms 32 P.06.02.03 113
12.06 DIO3 OUT PTR Bit pointer - 10 ms 32 P.06.01.10 113
12.07 DIO3 F OUT PTR Val pointer - 10 ms 32 P.01.01 113
12.08 DIO3 F MAX REAL 3…32768 Hz 1 = 1 10 ms 16 1000 113
12.09 DIO3 F MIN REAL 3…32768 Hz 1 = 1 10 ms 16 3 114
12.10 DIO3 F MAX SCALE REAL 0…32768 - 1 = 1 10 ms 16 1500 114
12.11 DIO3 F MIN SCALE REAL 0…32768 - 1 = 1 10 ms 16 0 114
12.12 RO1 OUT PTR Bit pointer - 10 ms 32 P.03.15.00 114
12.13 DI INVERT MASK UINT32 0…63 - 1 = 1 10 ms 16 0 115
12.14 DIO2 F MAX REAL 3…32768 Hz 1 = 1 10 ms 16 1000 115
12.15 DIO2 F MIN REAL 3…32768 Hz 1 = 1 10 ms 16 3 115