Standard function blocks
340
Outputs Reference output (REFOUTPUT): REAL
Output state (OUTSTATE): REAL
Output active (OUTACTIVE): Boolean
CYCLET
(10074)
Illustration
Execution time 0.00 µs
Operation Output (OUT) is the execution time of the selected function block.
Inputs -
Outputs Output (OUT): DINT. 1 = 1 µs
DATA CONTAINER
(10073)
Illustration
Execution time 0.00 µs
Operation Output (OUT) is the array data used by the XTAB and YTAB tables in block FUNG-1V
(page 340). Note that the array is defined with the output pin.
Inputs -
Outputs The output data type and the number of coordinate pairs are selected by the user.
Output (OUT): DINT, INT, REAL or REAL24
FUNG-1V
(10072)
Illustration
Execution time 9.29 µs
CYCLET
58
TLA1 1 msec (1)
OUT
OUT(58)
DATA CONTAINER
(DINT) 59
TLA1 1 msec (1)
OUT
OUT(59)
FUNG-1V
(DINT) 60
TLA1 1 msec (1)
BAL
BALREF
X
XTAB
YTAB
Y
Y(60)
BALREFO
BALREFO(60)
ERROR
ERROR(60)