Standard function blocks
293
OR
(10012)
Illustration
Execution time 1.55 µs (when two inputs are used) + 0.60 µs (for every additional input). When all
inputs are used, the execution time is 19.55 µs.
Operation The output (OUT) is 0, if all connected inputs (IN) are 0. Otherwise the output is 1.
Truth table:
The inputs can be inverted.
Inputs The number of inputs (2…32) is selected by the user.
Input (IN1…IN32): Boolean
Outputs Output (OUT): Boolean
ROL
(10013)
Illustration
Execution time 1.28 µs
Operation Input bits (I) are rotated to the left by the number (N) of bits defined by BITCNT. The N
most significant bits (MSB) of the input are stored as the N least significant bits (LSB) of
the output.
Example: If BITCNT = 3
Inputs The input data type is selected by the user.
Input (I): INT, DINT
Number of bits input (BITCNT): INT, DINT
OR
58
TLA1 1 msec (1)
IN1
IN2
OUT
OUT(58)
IN1 IN2 OUT
000
011
101
111
ROL
(DINT) 59
TLA1 1 msec (1)
BITCNT
I
O
O(59)
I 11100000111001011101001100110101
O 00000111001011101001100110101111
3 MSB
3 LSB