Parameter data
250
Actual signals (Parameter groups 1…9)
Index Name Type Range Unit FbEq Update
time
Data
length
PT Save
PF
Page
no.
01 ACTUAL VALUES
1.01 SPEED ACT REAL -30000…30000 rpm 1 = 100 250 µs 32 WP 77
1.02 SPEED ACT PERC REAL -1000…1000 % 1 = 100 2 ms 32 WP 77
1.03 FREQUENCY REAL -30000…30000 Hz 1 = 100 2 ms 32 WP 77
1.04 CURRENT REAL 0…30000 A 1 = 100 10 ms 32 WP 77
1.05 CURRENT PERC REAL 0…1000 % 1 = 10 2 ms 16 WP 77
1.06 TORQUE REAL -1600…1600 % 1 = 10 2 ms 16 WP 77
1.07 DC-VOLTAGE REAL - V 1 = 100 2 ms 32 WP 77
1.08 ENCODER 1 SPEED REAL - rpm 1 = 100 250 µs 32 WP 77
1.09 ENCODER 1 POS REAL24 - rev 1=100000000 250 µs 32 WP 77
1.10 ENCODER 2 SPEED REAL - rpm 1 = 100 250 µs 32 WP 78
1.11 ENCODER 2 POS REAL24 - rev 1=100000000 250 µs 32 WP 78
1.12 POS ACT REAL -32768…32767 * See 60.09 250 µs 32 WP 78
1.13 POS 2ND ENC REAL -32768…32767 revs 1 = 1 250 µs 32 WP 78
1.14 SPEED ESTIMATED REAL -30000…30000 rpm 1 = 100 2 ms 32 WP 78
1.15 TEMP INVERTER REAL24 -40…160 °C 1 = 10 2 ms 16 WP 78
1.16 TEMP BC REAL24 -40…160 °C 1 = 10 2 ms 16 WP 78
1.17 MOTOR TEMP REAL -10…250 °C 1 = 10 10 ms 16 WP 78
1.18 MOTOR TEMP EST INT32 -60…1000 °C 1 = 1 - 16 WP x 78
1.19 USED SUPPLY VOLT REAL 0…1000 V 1 = 10 10 ms 16 WP 78
1.20 BRAKE RES LOAD REAL24 0…1000 % 1 = 1 50 ms 16 WP 78
1.21 CPU USAGE UINT32 0…100 % 1 = 1 - 16 WP 78
1.22 INVERTER POWER REAL -2
31
…2
31
- 1 kW 1 = 100 10 ms 32 WP 78
1.26 ON TIME COUNTER INT32 0…35791394.1 h 1 = 100 10 ms 32 WP x 78
1.27 RUN TIME COUNTER INT32 0…35791394.1 h 1 = 100 10 ms 32 WP x 79
1.31 MECH TIME CONST REAL 0…32767 s 1 = 1000 10 ms 32 WP x 79
02 I/O VALUES
2.01 DI STATUS Pb 0…0x3F - 1 = 1 2 ms 16 WP 80
2.02 RO STATUS Pb - - 1 = 1 2 ms 16 WP 80
2.03 DIO STATUS Pb - - 1 = 1 2 ms 16 WP 80
2.04 AI1 REAL - V or mA 1 = 1000 2 ms 16 WP 80
2.05 AI1 SCALED REAL - - 1 = 1000 250 µs 32 WP 80
2.06 AI2 REAL - V or mA 1 = 1000 2 ms 16 WP 80
2.07 AI2 SCALED REAL - - 1 = 1000 250 µs 32 WP 80
2.08 AO1 REAL - mA 1 = 1000 2 ms 16 WP 80
2.09 AO2 REAL - V 1 = 1000 2 ms 16 WP 80
2.10 DIO2 FREQ IN REAL 0…32767 Hz 1 = 1000 2 ms 32 WP 80
2.11 DIO3 FREQ OUT REAL 0…32767 Hz 1 = 1000 2 ms 32 WP 80
2.12 FBA MAIN CW Pb 0 …
0xFFFFFFFF
- 1 = 1 500 µs 32 WP 81
2.13 FBA MAIN SW Pb 0 …
0xFFFFFFFF
-1 = 1 -32WP 84
2.14 FBA MAIN REF1 INT32 -2
31
…2
31
- 1 - 1 = 1 500 µs 32 WP 85