Parameters and firmware blocks
182
50.06 FBA ACT1 TR SRC FW block: FIELDBUS (see above)
Selects the source for fieldbus actual value 1 when parameter 50.04 FBA REF1 MODESEL / 50.05
FBA REF2 MODESEL is set to (0) RAW DATA.
Value pointer: Group and index
50.07 FBA ACT2 TR SRC FW block: FIELDBUS (see above)
Selects the source for fieldbus actual value 2 when parameter 50.04 FBA REF1 MODESEL / 50.05
FBA REF2 MODESEL is set to (0) RAW DATA.
Value pointer: Group and index
50.08 FBA SW B12 SRC FW block: FIELDBUS (see above)
Selects the source for freely programmable fieldbus status word bit 28 (2.13 FBA MAIN SW bit 28 SW
B12).
Bit pointer: Group, index and bit
50.09 FBA SW B13 SRC FW block: FIELDBUS (see above)
Selects the source for freely programmable fieldbus status word bit 29 (2.13 FBA MAIN SW bit 29 SW
B13).
Bit pointer: Group, index and bit
50.10 FBA SW B14 SRC FW block: FIELDBUS (see above)
Selects the source for freely programmable fieldbus status word bit 30 (2.13 FBA MAIN SW bit 30 SW
B14).
Bit pointer: Group, index and bit
50.11 FBA SW B15 SRC FW block: FIELDBUS (see above)
Selects the source for freely programmable fieldbus status word bit 31 (2.13 FBA MAIN SW bit 31 SW
B15).
Bit pointer: Group, index and bit