EasyManua.ls Logo

ABB ACSM1 - Page 270

ABB ACSM1
448 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault tracing
270
2006 EMERGENCY OFF
(0xF083)
Drive has received emergency
OFF2 command.
To restart drive, activate RUN ENABLE signal
(source selected by parameter 10.09 RUN
ENABLE) and start drive.
2007 RUN ENABLE
(0xFF54)
No Run enable signal is
received.
Check setting of parameter 10.09 RUN
ENABLE. Switch signal on (e.g. in the
fieldbus Control Word) or check wiring of
selected source.
2008 ID-RUN
(0xFF84)
Motor identification run is on. This alarm belongs to normal start-up
procedure. Wait until drive indicates that
motor identification is completed.
Motor identification is required. This alarm belongs to normal start-up
procedure.
Select how motor identification should be
performed, parameter 99.13 IDRUN MODE.
Start identification routines by pressing Start
key.
2009 EMERGENCY STOP
(0xF081)
Drive has received emergency
stop command (OFF1/OFF3).
Check that it is safe to continue operation.
Return emergency stop push button to normal
position (or adjust the fieldbus Control Word
accordingly).
Restart drive.
2010 POSITION SCALING
(0x8584)
Overflow or underflow in
position calculation (caused by
used position scaling).
Check position scaling parameter settings:
60.06 FEED CONST NUM60.09 POS
RESOLUTION.
Check speed scaling parameter settings:
60.11 POS SPEED2INT and 60.12 POS
SPEED SCALE.
2011 BR OVERHEAT
(0x7112)
Brake resistor temperature has
exceeded alarm limit defined by
parameter 48.07 BR TEMP
ALARMLIM.
Stop drive. Let resistor cool down.
Check resistor overload protection function
settings, parameters 48.0148.05.
Check alarm limit setting, parameter 48.07.
Check that braking cycle meets allowed
limits.
2012 BC OVERHEAT
(0x7181)
Brake chopper IGBT
temperature has exceeded
internal alarm limit.
Let chopper cool down.
Check resistor overload protection function
settings, parameters 48.01
48.05.
Check that braking cycle meets allowed
limits.
Check that drive supply AC voltage is not
excessive.
2013 DEVICE OVERTEMP
(0x4210)
Measured drive temperature
has exceeded internal alarm
limit.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against unit power.
Code Alarm
(fieldbus code)
Cause What to do

Table of Contents

Other manuals for ABB ACSM1

Related product manuals