INSTALLATION PROCEDURES
64 FOX615Installation
3.7 Fan unit or alarm unit (option)
3.7.1 Installing FAMO1 or FAMO1-F
Installation of the FAMO1 fan
unit or FAMO1-F alarm unit
Proceed as follows:
1. Locate the fixing position of the FAMO1 or FAMO1-F in the 19-inch rack
or within the ETSI adapters above the FOX subrack (refer to Figure 6
and Figure 15 respectively).
2. Lift the FAMO1 or FAMO1-F into position and secure the FAMO1 or
FAMO1-F using four M6 screws.
3. Tighten the M6 screws provisionally.
4. Fit the cable clips (21) and (22) provided with the FAMO1 or FAMO1-F
package to the left and right side of the FAMO1 or FAMO1-F front panel
(refer to Figure 36).
End of instruction
3.7.2 FOX interface
The FAMO1 or FAMO1-F power and alarm signals are connected via the
power and alarm cable to the FOX subrack.
Figure 35: FAMO1 or FAMO1-F power and alarm cable
Legend:
1 Subminiature-D connector (15 way) connects to the subrack
2 Molex connector (12 way) connects to the FAMO1 or FAMO1-F