Inspecting the oil level in axis-1 gearbox
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working
area.
1
WARNING
Handling gearbox oil involves several safety risks.
Before proceeding, please read the safety inform-
ation in the section Safety risks during work with
gearbox lubricants (oil or grease) on page 37.
2
CAUTION
The gearbox can contain an excessive pressure
that can be hazardous. Use caution when the oil
plug is opened, in order to let out the excess
pressure.
3
xx1500001993
Open the ventilation plug.
Note
The ventilation plug shall be opened prior to the
inspection plug, in order to release possible
pressure inside.
4
xx1500001992
Open the inspection plug.5
Inspect the oil level.6
Required oil level is a few millimeters below the
lower edge of the inspection hole.
7
Type of oil and total amount is de-
tailed in Technical reference
manual - Lubrication in gearboxes.
Add or drain oil, if required.8
Further information about how to
drain or fill with oil is found in sec-
tion Changing oil, axis-1 gearbox
on page 141.