NoteAction
Type of oil and total amount is de-
tailed in Technical reference
manual - Lubrication in gearboxes.
Add or drain oil, if required.8
Further information about how to
drain or fill with oil is found in sec-
tion Changing oil, axis-4 primary
gearbox on page 153.
Tightening torque: 24 Nm.Refit the oil plugs.9
DANGER
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in the section First test run may cause
injury or damage on page 27.
10
112 Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
3 Maintenance
3.3.3 Inspecting the oil level in axis-4 primary gearbox
Continued