Inspecting, mechanical stops
Use this procedure to inspect the additional mechanical stops.
NoteAction
DANGER
Turn off all:
• electric power supply
• hydraulic pressure supply
• air pressure supply
to the robot, before entering the robot working area.
1
Shown in figure Location of
mechanical stops on page 134.
Make sure no additional stops are damaged.2
Make sure the stops are properly attached.3
Correct tightening torque, additional mechanical
stops:
• Axis 1 = 300 Nm.
Article number is specified in
Required equipment on page 134.
If any damage is detected, the mechanical stops must
be replaced.
Correct attachment screws:
• M16x90 quality 12.9 Gleitmo 603 (2 pcs per
additional mechanical stop)
4
Product manual - IRB 8700 135
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
3 Maintenance
3.3.12 Inspecting the additional mechanical stops
Continued