Removing the brake release unit
Use these procedures to remove the brake release unit.
Preparations
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working area.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
please read the safety information in the section The
unit is sensitive to ESD on page 32
2
xx1300000743
Remove the push button guard from the SMB cover.
The push button guard must be removed to ensure
a correct refitting of the brake release unit.
3
xx1300000742
Remove the SMB cover.4
The battery can stay connected, to avoid needing to
synchronize the robot.
CAUTION
Carefully put the SMB cover down to avoid damaging
the battery cable connectors.
5
Continues on next page
Product manual - IRB 8700 243
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.4.4 Replacing the brake release unit
Continued

Table of Contents