ValueParameter
+55°C (+131°F)Maximum ambient temperature
+70°C (+158°F)Maximum ambient temperature (less than 24 hrs)
Maximum 95% at constant temper-
ature.
Maximum ambient humidity
Operating conditions, robot
The table shows the allowed operating conditions for the robot:
ValueParameter
+5°C
i
(41°F)Minimum ambient temperature
+50°C (122°F)Maximum ambient temperature
Maximum 95% at constant temper-
ature.
Maximum ambient humidity
i
At low environmental temperature (below 10° C) a warm-up phase is recommended to be run with
the robot. Otherwise there is a risk that the robot stops or runs with lower performance due to
temperature dependent oil and grease viscosity.
Protection classes, robot
The table shows the available protection types of the robot, with the corresponding
protection class.
Protection classProtection type
IP67Manipulator, protection type Foundry Plus
Product manual - IRB 8700 51
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.