NoteAction
Attachment screws: M5x12 8.8 (7 pcs)
xx1200001013
Refit the motor cover.
Note
Do not reuse the self-threading attachment
screws. Replace with standard attachment
screws or the threads will be damaged.
Note
Make sure the o-ring is properly fitted and
undamaged.
6
Make sure that the cover is tightly sealed.7
Concluding procedure
NoteAction
xx1600000046
Make sure the contact surface on the wrist
cover is undamaged.
1
Loctite 574
xx1600000048
Apply flange sealant (Loctite 574) on the
wrist cover flange.
2
Place the cable harness in a way so it will
not be damaged when the wrist cover is
fitted.
3
Continues on next page
Product manual - IRB 8700 613
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.7.4 Replacing the axis-5 motor
Continued