Tension Electronics PFEA113, User Manual
Section C.5.2 Inclined Mounting
3BSE029382R0101 Rev C C-5
C.5.2 Inclined Mounting
Sometimes it is necessary to mount the load cell on an 
incline due to mechanical design constraints of the 
machine or the need to have a proper force component 
applied to the load cell. 
Inclined mounting adds a component of tare force in the 
measuring direction and modifies the force components 
as shown.
NOTE
When calculating, it is important that the angles 
are set into the equations with the correct signs 
in relation to the horizontal plane.
PFTL 301E
F
R 
= T × [cos()cos()]
F
Rtot 
= F
R
 + F
RT 
= 
F
RT 
= Tare  × si n 
Tare
F
RT
F
R
T
T
+
T × [cos()cos()] + (Ta re ×  sin  )
Wrap gain
T
F
R
--------
T
T +cos 
–cos–
----------------------------------------------------------------------==
T (Tension) Wrap gain F
R
=
Wrap gain
1
+cos 
–cos–
-------------------------------------------------------------=
Tare
F
RT
F
R
T
T
+
+