Tension Electronics PFEA113, User Manual
Chapter 4 Operation
4-8 3BSE029382R0101 Rev C
4.7.1.4 Tension Values Connected to Analog Outputs, AO1 - AO6
Analog outputs, AO1-6, can be connected to different tension values corresponding to a number
of tension signal combinations.
See Section 3.12.7 Setting Analog Outputs (AO1-AO6).
Analog output tension menus:
AO1, Value
AO2, Value
AO3, Value
AO4, Value
AO5, Value
AO6, Value
4.7.2 Error and Warning Messages
An ERROR is something that causes the tension electronics to function incorrectly.
A WARNING is something that might affect the accuracy of the measurement.
When a warning or an error occurs, a warning or an error message is displayed on the
Operator Panel and the “Status” indication turns from green to red.
When is pressed the message disappears from the display.
If the problem that activated the warning or error message has disappeared the
“Status” indication turns to green.
If the error or warning remains the “Status” indication is red. Use the to step to the last
menu, where you can read the error or warning message.
For handling Error and Warning messages, see Chapter 6 Fault-tracing.