Tension Electronics PFEA113, User Manual
Chapter 3 Commissioning
3-8 3BSE029382R0101 Rev C
3.8.2 Performing Fast Setup using Wrap Gain
Follow the steps below to run a fast setup using Wrap Gain.
1Press for 5 seconds to go to the FastSetUp menu.
2Press to start the fast setup sequence.
3 Select web width if the unit is set to N/m, kN/m, kg/m or pli.
The same width is applied to Roll 1 and Roll 2.
4 Select number of rolls (1 or 2)
5 Select roll (1 or 2).
The menu is hidden if NumberOfRolls is set to [1].
6 Zero set is used to compensate for load cell zero signal and
tare weight.
Zero set must be done with no tension applied to the roll.
7 1. Check that no load is applied on the roll.
2. Press to zero set. āActionDoneā is shown on the
display for one second to confirm the zero setting action.
8 Select WrapGain from the list with and .
Confirm with .
9 Select the load cells (2, SingleSideA or SingleSideB) that
support the roll from the list with or . Confirm with .
10 Check the nominal load on the load cell name plate.
Select nominal load from the list with or .
Confirm with .
11 Enter the calculated wrap gain. For calculating wrap gain,
see Appendix (B, C, D, E, F or G) for installed load cell type.
Confirm with .
12 Select Voltage or Current from the list with or .
Confirm with .
WithNoTension
PressOkToZeroSet
NominalLoad
[1 kN 225 lbs]