EasyManua.ls Logo

ABB PFEA 113 - Performing Fast Setup Using Hanging Weights

ABB PFEA 113
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tension Electronics PFEA113, User Manual
Chapter 3 Commissioning
3-6 3BSE029382R0101 Rev C
3.8.1 Performing Fast Setup using Hanging Weights
The simplest method to set the wrap gain in this tension system is to use a known weight that
loads the center of the roll with a rope that follows the web path exactly.
Figure 3-1. Setting Wrap Gain with Hanging Weights (example of installation)
Follow the steps below to run a fast setup using hanging weights.
1Press for 5 seconds to go to the FastSetUp menu.
2Press to start the fast setup sequence.
3 Select web width if the unit is set to N/m, kN/m, kg/m or pli.
The same width is applied to Roll 1 and Roll 2.
4 Select number of rolls (1 or 2)
5 Select roll (1 or 2).
The menu is hidden if NumberOfRolls is set to [1].
6 Zero set is used to compensate for load cell zero signal and
tare weight.
Zero set must be done with no tension applied to the roll.
7 1. Check that no load is applied on the roll.
2. Press to zero set. ā€œActionDoneā€ is shown on the
display for one second to confirm the zero setting action.
8 Select HangingWeights from the list with and .
Confirm with .
Load cell
Weight
Rope
supported roll
All rolls must be
free turning idlers.
To keep friction
losses low, only
use the closest
rolls to define web
path.
WebTension
> 5
seconds
FastSetUp
SetWebWidth
XXXXXX
NumberOfRolls
[2]
Roll 1 or 2
[1]
ZeroSet A, B
[ZZ]
SetWrapGain
[HangingWeights]

Table of Contents